Assessment of the utility of optically pumped magnetometer magnetoencephalography in preoperative localization of refractory epilepsy: A prospective study
Yuanzhong Shen, Chao You, Y X Zhang, Nan Ji, Xu Zhao, Ping Zhang, Shanshan Huang, Huicong Kang 等 20 位
Tongji Hospital Huazhong University of Science and Technology Capital Medical University Beijing Tian Tan Hospital
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
OBJECTIVE: Precise localization of the epileptogenic zone (EZ) is crucial for epilepsy surgery success. Optically pumped magnetometer magnetoencephalography (OPM-MEG) is a promising noninvasive technique requiring rigorous clinical validation. METHODS: In this prospective diagnostic study, 68 patients with refractory epilepsy underwent 90-min interictal OPM-MEG. Dipoles were fitted to interictal epileptiform discharges for localization. The primary objective was to evaluate the spatial concordance between OPM-MEG and the EZ defined by intracranial electroencephalography (iEEG; stereo-EEG or electrocorticography), assessed at the sublobar level using Gwet AC1. The secondary objective was to evaluate the diagnostic value of OPM-MEG for surgical outcome. This analysis included 51 patients who underwent curative intervention (resection or thermocoagulation). The reference standard was a composite of the treated brain region and seizure freedom (International League Against Epilepsy [ILAE] class 1 or Engel class I) at ≥12-month follow-up, from which sensitivity, specificity, and diagnostic odds ratio (OR) were calculated. RESULTS: OPM-MEG showed almost perfect agreement with iEEG-based EZ localization overall (AC1 = .885, concordance rate = 90.0%), with substantial agreement in temporal (80.1%, AC1 = .723) and almost perfect agreement in extratemporal regions (92.0%, AC1 = .926). The Euclidean centroid distance between OPM-MEG and iEEG localizations was significantly shorter in concordant versus discordant cases. In the assessment of diagnostic value, OPM-MEG demonstrated a sensitivity of 85.7% and specificity of 65.2% (OR = 11.25) under ILAE criteria, and a sensitivity of 73.0% and specificity of 64.3% (OR = 4.86) under Engel criteria. SIGNIFICANCE: OPM-MEG demonstrates high concordance with iEEG for EZ localization and provides robust diagnostic value for predicting postoperative seizure freedom, supporting its utility in the presurgical evaluation of refractory epilepsy.
逐年被引趋势
暂无年度引用数据
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
物理Atomic and Subatomic Physics Research
Epilepsy research and treatment · Functional Brain Connectivity Studies
参考文献 43
此处列出前 3 条