Visualization of small vibrations inside an MRI scanner using video motion amplification
Youngseob Seo, Zhiyue Wang
Korea Research Institute of Standards and Science The University of Texas Southwestern Medical Center
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
Background Diffusion‐weighted magnetic resonance imaging (DW‐MRI) acquisition requires the application of strong magnetic field gradients, which can induce mechanical vibrations in tissues or phantoms, potentially leading to signal loss or degradation. A qualitative assessment of these vibrations would be valuable for quality assurance (QA). Conventional methods, such as piezoelectric accelerometers and laser interferometry, have limitations in their applicability and availability. There remains a need for a readily accessible method to detect and characterize these vibrations as part of a robust QA protocol. Purpose The objective of this study is to investigate the feasibility of using motion amplification of high‐speed video to assess vibrations during DW‐MRI scanning. Methods A gel phantom simulating a human head was positioned supine within a head receive coil inside an MRI scanner. A 45‐degree angled mirror was placed to visualize the phantom's face, while a high‐speed camera, positioned outside the scanner, was used to record videos under two conditions: (1) the scanner in an idle state (still condition), and (2) during a DW‐MRI scan (vibration condition). The recorded videos were processed using a motion amplification software tool to enhance subtle movements. The motion of multiple position markers affixed to the phantom was quantitatively analyzed. Results No motion was visible to the naked eye under either still or scanning conditions. However, motion amplification revealed clear marker displacement during DW‐MRI, with substantially smaller movement during scanner idling. Across all facial markers and directions (X (L‐R), Y (A‐P) and Z (I‐S)), median root‐mean‐square displacement increased from 0.85 µm (range: 0.61–1.50 µm) at idle to 2.59 µm (2.04–4.31 µm) during DW‐MRI scanning (b = 2500 s/mm 2 ). Similarly, median peak‐to‐peak displacement rose from 7.71 µm (3.92–10.37 µm) to 18.47 µm (15.22–31.77 µm). Conclusions Motion amplification of high‐speed video provides a viable method for detecting and analyzing vibrations during MRI scans. This approach could serve as a valuable tool for QA, offering an alternative to conventional vibration assessment techniques.
逐年被引趋势
暂无年度引用数据
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
生物医学Advanced MRI Techniques and Applications
Ultrasound Imaging and Elastography · Advanced Neuroimaging Techniques and Applications