Numerical Investigation and Cross‐Section Type Selection of Concrete‐Filled Double Steel Plate (CFDSP) Composite Shear Walls Under Cyclic Loading
Omer Cobanoglu, Xiangyong Ni, Bin Zhao
Tongji University Shanghai University
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
Concrete‐filled double steel plate (CFDSP) composite shear walls have excellent seismic performance and are generally used as lateral resistance for high‐rise buildings. However, the numerical simulation of such walls is complicated because of the complex contact between the concrete, the external steel plate, and the shear studs. Eighteen CFDSP walls in the present literature were numerically simulated under cyclic and constant axial loading, and the accuracy was evaluated by comparing them with the experimental results. Then, the impact of cross‐section variations on the structural performance of CFDSP walls under the same steel content ratio was numerically investigated. Designed numerical walls were evaluated under the same loading conditions with four distinct cross‐sections for comparative analysis. Finally, parametric analysis was performed to observe the influence of aspect ratio, steel thickness, and stud spacing on the seismic performance of CFDSP walls. The analysis results show that the proposed numerical model can accurately recover the hysteretic curves of CFDSP walls regarding strength reduction, energy dissipation, and pinch behavior.
逐年被引趋势
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
工程Structural Load-Bearing Analysis
Seismic Performance and Analysis · Seismic and Structural Analysis of Tall Buildings