Thermal performance analysis of reflux condensation in vertical tubes via pure steam
Samah A. Albdour, Sameer Osman, Mubashir Hassan, Ho Joon Yoon, Imran Afgan, Yacine Addad
Khalifa University of Science and Technology Abu Dhabi Health Services University of Manchester
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
Reflux condensation in the U-tubes of a steam generator (SG) plays a vital role in removing heat in pressurized water reactors (PWRs) during mid-loop operations and/or accidents. To evaluate the efficacy of reflux condensation in SG U-tubes, a comprehensive understanding of the heat transfer characteristics associated with pure steam is necessary. Therefore, this study performs experiments to examine the reflux condensation of pure steam within a vertical tube with an inner diameter of 19 mm and an outer diameter of 22 mm. The steam bulk temperatures were systematically altered at 10-degree intervals within the range of 120–150 °C, and the steam Reynolds number ranged from 4876 to 20,430. Throughout, the temperature of the coolant within the cooling jacket and its rate of flow remained constant at 55 °C and 8 L/min, respectively. Validation via the TRACE system code confirmed good agreement with the experimental results, further bolstering confidence in the consistency of the current findings with the data previously used to calibrate and refine the correlations within the system code.
逐年被引趋势
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
工程Heat Transfer and Boiling Studies
Nuclear Engineering Thermal-Hydraulics · Refrigeration and Air Conditioning Technologies
参考文献 18
此处列出前 3 条