On adaptive MPC development and application to a DC fast charger (DCFC) station with an embedded microgrid
Fhazhil Wamalwa, Tunmise Raji, Reagan Wafula, Courage Ekoh
San Francisco State University Rochester Institute of Technology Institut d'Etudes Politiques de Paris
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
This paper proposes a parameter-adaptive model predictive control (MPC) for a high-utilization DC fast-charger (DCFC) station with an embedded solar-PV/battery microgrid, treating the stationary battery energy storage (BES) charging and discharging coefficients as uncertain parameters estimated online. The control problem is formulated as a multi-objective quadratic program to minimize grid-import and BES-degradation costs while maximizing self-consumption of on-site generated solar-PV power. The application of the proposed model to a practical case study demonstrates strong capabilities of the developed MPC, reducing overall annual energy costs by 71 % and grid peak demand charges by up to 52 %, a superior performance when compared to 65 % grid energy cost and 23 % peak demand cost savings achieved by the open-loop optimal control (OLOC) strategy formulated for the same case study problem. The analysis of the obtained results over different temporal scales–daily and weekly–across different seasons of the year shows the MPC’s capabilities to aggressively handle the model objectives and constraints amid uncertainties in solar PV generation and the charging station’s demand to realize lower overall system costs, thanks to its feedback control capabilities. These findings underscore the MPC’s robustness and practicality for real-world renewable energy-based DCFC applications. The obtained results can be used as a framework of reference when planning integration of renewable-based microgrids in electric vehicle (EV) charging infrastructure. • An adaptive MPC strategy is developed for energy management in a DC fast charging station. • MPC achieves up to 71 % reduction in grid energy costs by minimizing imports and maximizing local solar usage. • MPC consistently outperforms open-loop control across daily and weekly timescales under uncertainty. • Peak grid power demand is reduced by up to 50 % on some days using MPC compared to its open-loop counterpart.
逐年被引趋势
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
工程Microgrid Control and Optimization
Advanced DC-DC Converters · Advanced Battery Technologies Research
参考文献 53
此处列出前 3 条
引用本文 5
按被引量排序,此处列出前 3 条