Carboxyhemoglobin and methemoglobin levels to diagnose hemolysis in patients supported with mechanical circulatory support devices
Ingrid L. Rodgers, Daniel Yip, Parag C. Patel, Cesar A. Keller
Jacksonville College Mayo Clinic in Florida
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
Background: Decreased systemic oxygen delivery derived from gas exchange abnormalities in severe hemolysis complicates patients requiring mechanical circulatory support devices. Severe hemolysis releases free hemoglobin in plasma causing elevation of carboxyhemoglobin and methemoglobin levels. Hemolysis-induced decline in hemoglobin and oxyhemoglobin saturation significantly reduces the arterial oxygen content in blood, reducing systemic oxygen delivery. These patients develop hypoxemia with misleadingly normal oxygen saturation measured by standard pulse oximetry. Methods: Retrospective review of 2 clinical cases reaching carboxyhemoglobin and methemoglobin levels > 2% while supported with an Impella device. Results: Case 1. Patient with cardiogenic shock refractory to maximal medical therapy required insertion of Impella device achieving improvement in cardiac output, pulse oximetry, arterial oxygen saturation and systemic oxygen delivery. The device caused significant hemolytic anemia with severe decline in hemoglobin and arterial oxygen saturation with elevation of carboxyhemoglobin and methemoglobin levels, causing drastic reduction in systemic oxygen delivery despite adequate cardiac output. Device removal reversed severe hemolytic anemia, causing increased arterial oxygen saturation and systemic oxygen delivery despite borderline cardiac output.Case 2. Patient with refractory cardiogenic shock improved after insertion of Impella device. Initial improvement cardiac output and systemic oxygen delivery was negated by hemolytic anemia associated with elevation of carboxyhemoglobin and methemoglobin levels. Hemolysis decreased by reducing the Impella power output. Carboxyhemoglobin and methemoglobin levels correlated precisely with degree of hemolysis allowing to titrate therapy to best systemic oxygen delivery. Conclusions: Monitoring carboxyhemoglobin and methemoglobin levels readily identifies patients with ongoing hemolysis secondary to invasive supportive devices.
逐年被引趋势
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
生物医学Heme Oxygenase-1 and Carbon Monoxide
Hemoglobin structure and function · Cardiac Arrest and Resuscitation
参考文献 20
此处列出前 3 条
引用本文 3
按被引量排序,此处列出前 3 条