Localiser radiographs in CT: Current practice, radiation dose, image quality and clinical applications
Yazan Al‐Hayek, Bismark Ofori-Manteaw, N Frame, Kelly Spuur, Xiaoming Zheng, Lorraine Rose, Ming‐Tak Chau
Charles Sturt University
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
INTRODUCTION: Survey or localiser radiographs are integral to CT imaging. However, the diverse functions and roles of the localiser radiograph are often obscure to radiographers and radiologists. This scoping review reports the full scope of localiser radiograph use and function in contemporary CT imaging. METHODS: A scoping review was performed. A systematic literature search was conducted using four databases: MEDLINE, CINAHL, Emcare and Scopus from January 2013 to December 2023. Data extraction was conducted by two review authors and validated by a third reviewer. Thirty-six studies were included in this review. RESULTS: Three major themes emerged: radiation dose management, image quality considerations and clinical protocol applications. Specifically, the number, order of selection and directions of localiser radiographs significantly impact patient dose and image quality; which are additionally impacted by off-centre patient positioning, which can influence the accuracy of body size estimates and CT numbers. Finally, the optimal selection of localiser radiographs, including exposure parameters (kVp, mAs), can be a part of clinical task-based imaging protocol optimisation. CONCLUSIONS: The utilities of localiser radiographs in CT imaging are varied. It is salient that radiographers and radiologists understand their role and the impacts of poor application to ensure that radiation dose is minimised and image quality maximised through correct use. Radiographers and radiologists should also be aware of the impact of poor patient positioning on ACTM function, dose and image quality. Additionally, localiser radiographs should be used for clinical task-based protocol optimisation. IMPLICATIONS FOR PRACTICE: The number, order of selection, direction, patient off-centring, and exposure parameters must be considered when utilising localiser radiographs as they impact dose, image quality, and protocol applications. It is essential for radiographers and radiologists to understand these impacts.
逐年被引趋势
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
生物医学Radiation Dose and Imaging
Advanced X-ray and CT Imaging · Medical Imaging Techniques and Applications
参考文献 58
此处列出前 3 条
引用本文 7
按被引量排序,此处列出前 3 条