Low-voltage, ultra-broadband wearable MEMS ultrasound: a frequency-merged, wafer-scale framework for continuous in vivo cardiovascular imaging and monitoring
Tong Jin, Chenfang Yan, Yucheng Lin, Hongyang Chen, 乔奕, Zijie Zhao, Rui Wang, Qiong He 等 15 位
Chinese Academy of Sciences Institute of Microelectronics University of Chinese Academy of Sciences Tsinghua University
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
Continuous, non-invasive monitoring of central hemodynamics is essential for advanced cardiovascular care. Although wearable ultrasound enables deep-tissue sensing, its widespread clinical adoption is limited by the inherent physical trade-off between driving voltage and acoustic bandwidth, alongside the challenges of scaling microelectronic ultrasound devices for medical imaging. Here, we report a wearable, 81.7% broadband piezoelectric micromachined ultrasonic transducer (pMUT) array driven at a low voltage of 5 Vp. To address these bottlenecks, this study introduces two parallel innovations. First, we introduce a novel frequency-merging design, quantified by an equivalent circuit model, to effectively decouple the voltage-bandwidth trade-off. Second, we provide a comprehensive framework directing a scalable silicon-on-insulator wafer-level fabrication process towards fully in vitro and in vivo experimental characterizations for medical imaging. Enabled by these advancements, in vitro characterization demonstrates 0.64 mm axial and 1.27 mm lateral resolutions while maintaining a penetration depth of up to 9 cm in wire phantoms. In vivo, the wearable patch achieves comparable high-fidelity B-mode and M-mode imaging of carotid, brachial, and radial arteries within 4 cm depth to commercial rigid probes. Crucially, the device enables continuous, stable hemodynamic monitoring under limited daily postural activities for up to 9 hours. Inter-subject validation confirms precise blood pressure measurements, with deviations of 2.2 mmHg compared to FDA-approved clinical monitors. Leveraging standard semiconductor batch manufacturing, this work addresses the technical mismatch between low-voltage wearable devices and high-performance ultrasound transduction, creating a feasible development path for highly integrated, mass-producible cardiovascular ultrasound systems-on-chip.
逐年被引趋势
暂无年度引用数据
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
工程Ultrasonics and Acoustic Wave Propagation
Ultrasound Imaging and Elastography · Non-Invasive Vital Sign Monitoring