Electrochemical sensor based on α-Fe2O3/rGO core-enhanced carbon interfaces for ultra-sensitive metronidazole detection
Abdulrahman Saad Alqahtani, Hashim Elshafie, Azath Mubarakali, Asma AlJarullah, P. Parthasarathy, M. Venkatesh, Adarsh Rag S
University of Bisha King Khalid University CMR University Manipal Academy of Higher Education
内容与影响
In this work, we describe the creation of a new magneto-electrochemical biosensor that detects metronidazole (MTZ), an antibiotic that is frequently used to treat anaerobic bacterial and protozoal infections, with extreme sensitivity. The sensor platform is engineered by integrating α-Fe 2 O 3 magnetic core nanoparticles with reduced graphene oxide (rGO) to fabricate a core-enhanced carbon electrode (α-Fe₂O₃/rGO@CE). The synergistic combination of α-Fe 2 O 3 and rGO significantly enhances the electrocatalytic activity, electron transfer rate, and surface area of the sensing interface. Using X-ray diffraction (XRD), electrochemical impedance spectroscopy (EIS), and scanning electron microscopy (SEM), structural and morphological characterizations were carried out to verify the uniform distribution of spherical α-Fe 2 O 3 nanoparticles (~ 25 nm) anchored on rGO nanosheets. Electrochemical performance was systematically investigated through cyclic voltammetry (CV) and Differential Pulse voltammetry (DPV). When compared to the unmodified Counter Electrode (CE) (-0.65 V against Ag/AgCl), the suggested biosensor showed a notable change in the metronidazole reduction peak to a higher positive potential (-0.4 V vs. Ag/AgCl), suggesting superior catalytic efficiency. With a remarkable limit of identification (LOD) of 2.80 × 10 −6 M and a limit of quantization (LOQ) of 8.0 × 10 −6 M, a broad linear detection range of 8.0 × 10 −6 to 1.0 × 10 −5 M was attained. The sensor was effectively used for the quantitative measurement of metronidazole in medication and in human urine samples (collected from Mangalore Medical Centre with informed consent obtained from the respective patients, ensuring ethical compliance for clinical analysis) due to its exceptional sensitivity, stability, and reproducibility. This study demonstrates how α-FeO₃/rGO hybrid nanomaterials can be used to create effective magneto-electrochemical biosensors for use in clinical and pharmaceutical diagnostic settings.
逐年被引趋势
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
回答优先基于摘要、文献信息与可获取全文;依据不足时会明确说明。
学术脉络
学科主题
生物医学Advanced biosensing and bioanalysis techniques
Electrochemical Analysis and Applications · Electrochemical sensors and biosensors
参考文献 25
此处列出前 3 条
施引文献 5
按被引量排序,此处列出前 3 条