Improving CTC isolation by controlling orbit engagement in inertial microfluidics
Chiara Francesca Ghera, Roslyn Hay, Jian Zhou, Benjamin Owen, Ian Papautsky
University of Illinois Chicago University of Edinburgh Rush University Medical Center
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
Inertial microfluidics provides a label-free strategy for isolating circulating tumor cells (CTCs) from blood by exploiting size-dependent lateral migration in microchannels. However, straight-channel devices are often optimized using the final equilibrium position, even though target-cell loss can arise from incomplete or poorly reproducible migration before outlet collection. Here, we show that heteroclinic orbit engagement provides a predictive design criterion for improving CTC scale separation in a rectangular co-flow inertial microchannel. A computational model predicted size-dependent heteroclinic orbits and lateral migration velocities, which were experimentally validated using beads under controlled inlet flow-split conditions. Increasing buffer confinement shifted the sample-buffer interface closer to the sidewall, promoted earlier orbit engagement, improved agreement between measured and simulated velocity profiles, and reduced upstream trajectory variability. Larger CTC scale particles engaged their orbits earlier and migrated more reproducibly, while smaller white blood cell (WBC) scale particles remained laterally displaced from the larger particle focusing region. Biological validation with PANC1 and A549 cells showed that the 1 : 6 : 1 flow-split configuration increased separation efficiency to 99.9 ± 0.2% for PANC1 and maintained high separation efficiency of 99.2 ± 0.9% for A549 cells, although its effect on total recovery was cell line dependent. In an intraductal papillary mucinous neoplasm (IPMN) patient sample, representing a premalignant pancreatic lesion that may progress to invasive pancreatic ductal adenocarcinoma (PDAC), CTC target outlet partitioning was 67% under 1 : 1 : 1 and 100% under 1 : 6 : 1, within the limits of the detected cell numbers. These results establish orbit engagement as a mechanistic design principle for improving clinically relevant CTC enrichment without changing device geometry, total flow rate, or labeling strategy.
逐年被引趋势
暂无年度引用数据
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
工程Microfluidic and Bio-sensing Technologies
Microfluidic and Capillary Electrophoresis Applications · Field-Flow Fractionation Techniques
参考文献 32
此处列出前 3 条