A structured light laser probe for gastrointestinal polyp size measurement: a preliminary comparative study
Marco Visentini-Scarzanella, Hiroshi Kawasaki, Ryo Furukawa, Marco Augusto Bonino, Simone Arolfo, Giacomo Lo Secco, Alberto Arezzo, Arianna Menciassi 等 10 位
Kagoshima University Kyushu University Hiroshima City University University of Turin
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
Background and study aims Polyp size measurement is an important diagnostic step during gastrointestinal endoscopy, and is mainly performed by visual inspection. However, lack of depth perception and objective reference points are acknowledged factors contributing to measurement errors in polyp size. In this paper, we describe the proof-of-concept of a polyp measurement device based on structured light technology for future endoscopes. Patients and methods Measurement accuracy, time, user confidence, and satisfaction were evaluated for polyp size assessment by (a) visual inspection, (b) open biopsy forceps of known size, (c) ruled snare, and (d) structured light probe, for a total of 392 independent polyp measurements in ex vivo porcine stomachs. Results Visual assessment resulted in a median estimation error of 2.2 mm, IQR = 2.6 mm. The proposed probe can reduce the error to 1.5 mm, IQR = 1.67 mm (P = 0.002, 95 %CI) and its performance was found to be statistically similar to using forceps for reference (P = 0.81, 95 %CI) or ruled snare (P = 0.99, 95 %CI), while not occluding the tool channel. Timing performance with the probe was measured to be on average 54.75 seconds per polyp. This was significantly slower than visual assessment (20.7 seconds per polyp, P = 0.005, 95 %CI) but not significantly different from using a snare (68.5 seconds per polyp, P = 0.73, 95 %CI). However, the probe’s timing performance was partly due to lens cleaning problems in our preliminary design. Reported average satisfaction on a 0 – 10 range was highest for the proposed probe (7.92), visual assessment (7.01), and reference forceps (7.82), while significantly lower for snare users with a score of 4.42 (P = 0.035, 95 %CI). Conclusions The common practice of visual assessment of polyp size was found to be significantly less accurate than tool-based assessment, but easy to carry out. The proposed technology offers an accuracy on par with using a reference tool or ruled snare with the same satisfaction levels of visual assessment and without occluding the tool channel. Further study will improve the design to reduce the operating time by integrating the probe within the scope tip.
逐年被引趋势
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
生物医学Colorectal Cancer Screening and Detection
Optical measurement and interference techniques · Optical Imaging and Spectroscopy Techniques
参考文献 17
此处列出前 3 条
引用本文 27
按被引量排序,此处列出前 3 条