Microwave resonator probe for localized density measurements in weakly magnetized plasmas
R. L. Stenzel
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
A simple diagnostic tool for performing spatially resolved density measurements in a large, weakly magnetized, low-temperature plasma is described. The principle is based on a microwave technique to determine the cold plasma dielectric property ε=1−ωp2/ω2, where ωp is the electron plasma frequency. A parallel-wire quarter-wavelength resonator is immersed into the plasma, the resonance frequency (ωres≳ωp) is measured and the density derived from the simple relation ωp2=ω2res−ω2res(ε=1). In contrast to the familiar cavity resonance shift method, the present method is suited for localized density measurements. The spatial resolution is comparable to the size of the resonator (2-mm width×8 mm length, fres=7.45 GHz). The microwave technique is largely independent of sheath and thermal effects and is thus more reliable than probe measurements in nonuniformly rf-heated magnetoplasmas. A comparison with independent density diagnostic tools is presented and additional applications are pointed out.
逐年被引趋势
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
物理Dust and Plasma Wave Phenomena
Plasma Diagnostics and Applications · Magnetic confinement fusion research
参考文献 10
此处列出前 3 条
引用本文 244
按被引量排序,此处列出前 3 条