Direct observation of nanometer-scale Joule and Peltier effects in phase change memory devices
Kyle L. Grosse, Feng Xiong, Sungduk Hong, William P. King, Eric Pop
University of Illinois Urbana-Champaign
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
We measure power dissipation in phase change memory (PCM) devices by scanning Joule expansion microscopy (SJEM) with ∼50 nm spatial and 0.2 K temperature resolution. The temperature rise in the Ge2Sb2Te5 (GST) is dominated by Joule heating, but at the GST-TiW contacts it is a combination of Peltier and current crowding effects. Comparison of SJEM and electrical measurements with simulations of the PCM devices uncovers a thermopower of ∼350 μV K−1 and a contact resistance of ∼2.0 × 10−8 Ω m2 (to TiW) for 25 nm thick films of face centered-cubic crystalline GST. Knowledge of such nanometer-scale Joule, Peltier, and current crowding effects is essential for energy-efficient design of future PCM technology.
逐年被引趋势
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
材料 / 化学Phase-change materials and chalcogenides
Advanced Thermoelectric Materials and Devices · Advanced Memory and Neural Computing