A ROBUST MART ALGORITHM FOR TOMOGRAPHIC APPLICATIONS
K. Muralidhar Debasish Mishra
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
The present work is concerned with the development of a robust reconstruction algorithm for applications involving tomography. In an earlier study it was shown that among the ART family of algorithms, the multiplicative algebraic reconstruction algorithm (MART) was the most appropriate for tomographic reconstruction [1]. In the present work, the MART algorithm has been extended so that (a) its performance is now acceptable over a wider range of relaxation factors, (b) the time requirement for convergence to a solution is lower, and (c) its performance is less sensitive to noise in the projection data. Applications considered for evaluating the proposed algorithms are (1) a circular region with holes, (2) a three-dimensional temperature field in a differentially heated fluid layer, and (3) experimental data recorded in a differentially heated fluid layer using an interferometer. The proposed algorithms are seen to be an improvement over those presently available, for all three examples considered.
逐年被引趋势
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
生物医学Medical Imaging Techniques and Applications
Advanced MRI Techniques and Applications · Electrical and Bioimpedance Tomography
参考文献 15
此处列出前 3 条
引用本文 75
按被引量排序,此处列出前 3 条