Detection of motor-evoked potentials below the noise floor: rethinking the motor stimulation threshold
Zhongxi Li, Angel V. Peterchev, John C. Rothwell, Stefan M. Goetz
Duke University University College London University of Cambridge Duke University Hospital
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
Objective . Motor-evoked potentials (MEPs) are among the most prominent responses to brain stimulation, such as supra-threshold transcranial magnetic stimulation and electrical stimulation. Understanding of the neurophysiology and the determination of the lowest stimulation strength that evokes responses requires the detection of even smaller responses, e.g. from single motor units. However, available detection and quantization methods suffer from a large noise floor. This paper develops a detection method that extracts MEPs hidden below the noise floor. With this method, we aim to estimate excitatory activations of the corticospinal pathways well below the conventional detection level. Approach . The presented MEP detection method presents a self-learning matched-filter approach for improved robustness against noise. The filter is adaptively generated per subject through iterative learning. For responses that are reliably detected by conventional detection, the new approach is fully compatible with established peak-to-peak readings and provides the same results but extends the dynamic range below the conventional noise floor. Main results . In contrast to the conventional peak-to-peak measure, the proposed method increases the signal-to-noise ratio by more than a factor of 5. The first detectable responses appear to be substantially lower than the conventional threshold definition of 50 µ V median peak-to-peak amplitude. Significance . The proposed method shows that stimuli well below the conventional 50 µ V threshold definition can consistently and repeatably evoke muscular responses and thus activate excitable neuron populations in the brain. As a consequence, the input–output (IO) curve is extended at the lower end, and the noise cut-off is shifted. Importantly, the IO curve extends so far that the 50 µ V point turns out to be closer to the center of the logarithmic sigmoid curve rather than close to the first detectable responses. The underlying method is applicable to a wide range of evoked potentials and other biosignals, such as in electroencephalography.
逐年被引趋势
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
生物医学Transcranial Magnetic Stimulation Studies
Muscle activation and electromyography studies · EEG and Brain-Computer Interfaces
参考文献 48
此处列出前 3 条
引用本文 31
按被引量排序,此处列出前 3 条