Accuracy and Validity of Stitching Sectional Cone Beam Computed Tomographic Images
Moon-Key Kim, Sang‐Hoon Kang, Eunha Lee, Sang-Hwy Lee, Wonse Park
Yonsei University National Health Insurance Service Ilsan Hospital National Health Insurance Service
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
To determine whether three-dimensionally reconstructed images of skulls created by stitching multiple cone beam computed tomographic (CBCT) images are as accurate as single images obtained using multidetector computed tomography (MDCT), 10 skull models were scanned using an optical three-dimensional scanner, MDCT, and CBCT. Cone beam CT images at 3 different levels of the skull were manually superimposed and stitched. The reconstructed CBCT images at each level were aligned and fused using computer software and then compared to the nominal reference image obtained from the optical three-dimensional scanner by determining positional errors. The reconstructed MDCT images were also compared, and the differences in the mean errors for the 3 image types compared with the nominal reference image data were evaluated. There were no significant differences between the MDCT images and the manually merged CBCT images (Wilcoxon signed rank test, P = 0.017). In contrast, there were significant differences between the MDCT images and the software-aligned CBCT images (P = 0.005). Manual stitching of CBCT sectional images at different levels can provide accurate anatomic details of the oral and maxillofacial regions.
逐年被引趋势
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
生物医学Dental Radiography and Imaging
Medical Imaging Techniques and Applications · Advanced X-ray and CT Imaging
参考文献 9
此处列出前 3 条
引用本文 19
按被引量排序,此处列出前 3 条