NEXUS Arch: A Multicenter Study Evaluating the Initial Experience With a Novel Aortic Arch Stent Graft System
David Planer, Gabby Elbaz‐Greener, Nicola Mangialardi, Thomas F. Lindsay, Augusto D’Onofrio, Hubert Schelzig, Lyubov Chaykovska, Andrew Hill 等 16 位
Hadassah Medical Center Azienda Ospedaliera San Camillo-Forlanini Ospedale San Filippo Neri Ospedale generale di zona San Camillo Treviso
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
OBJECTIVE: To assess the initial clinical experience with a novel endograft system (NEXUS Aortic Arch Stent Graft System) designed to treat aortic arch pathologies and address the morphology and hemodynamic challenges of the aortic arch. SUMMARY BACKGROUND DATA: The aortic arch remains the most challenging part of the aorta for both open and endovascular repair. Transcatheter aortic arch repair has the potential to significantly reduce surgical risks. METHODS: Patients underwent transcatheter aortic arch repair with a single branch, 2 stent graft system, implanted over a through-and-through guidewire from the brachiocephalic trunk, to the descending aorta with an ascending aorta stent graft. The ascending aorta stent graft is deployed into a designated docking sleeve to connect the 2 stent grafts and isolate the aortic arch pathology. Proximal landing zone in all cases was in Zone 0. Anatomical inclusion criteria included adequate landing zone in the ascending aorta, brachiocephalic trunk, and descending thoracic aorta. Preparatory debranching procedure was performed in all patients with carotid-carotid crossover bypass and left carotid to left subclavian bypass, or parallel graft from descending aorta to left subclavian artery. Safety and performance were evaluated through 1 year. Survival analysis used the Kaplan-Meier method. RESULTS: Twenty-eight patients, 79% males, with a mean age of 72.2 ± 6.2 years were treated with 100% procedural success. Isolated aortic arch aneurysm was the principle pathology in 17 (60.7%) of patients, while chronic aortic dissection was the principle pathology in 6 (21.4%) of patients. The remaining 5 (17.8%) had combined or other pathologies. At 1 month, the vascular pathology was excluded in 25 of 26 alive patients (96.1%). The 30 days mortality rate was 7.1%, stroke rate was 3.6% (all nondisabling), and combined mortality/stroke rate was 10.7%. One-year mortality was 10.7%, without device or aneurysm-related death. Two patients (7.1%) reported stroke or transient ischemic attack at 1 year that recovered completely. One year combined mortality/stroke rate was 17.8%. There were 3 patients (10.7%) that had device-related unplanned reinterventions through 1 year. CONCLUSIONS: The NEXUS Aortic Arch Stent Graft System, a novel single branch, 2 stent graft system used for endovascular aortic arch repair that requires landing in the ascending aorta, demonstrates a high success rate with excellent 1 year safety and performance.
逐年被引趋势
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
生物医学Aortic Disease and Treatment Approaches
Tracheal and airway disorders · Aortic aneurysm repair treatments
参考文献 24