Superconducting TESLA cavities
B. Aune, R. Bandelmann, D. Bloess, B. Bonin, A. Bosotti, Mark S. Champion, C. Crawford, G. Deppe 等 53 位
Commissariat à l'Énergie Atomique et aux Énergies Alternatives CEA Paris-Saclay Deutsches Elektronen-Synchrotron DESY European Organization for Nuclear Research
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
The conceptional design of the proposed linear electron-positron collider TESLA is based on 9-cell 1.3 GHz superconducting niobium cavities with an accelerating gradient of ${E}_{\mathrm{acc}}\ensuremath{\ge}25\mathrm{MV}/\mathrm{m}$ at a quality factor ${Q}_{0}\ensuremath{\ge}5\ifmmode\times\else\texttimes\fi{}{10}^{9}$. The design goal for the cavities of the TESLA Test Facility (TTF) linac was set to the more moderate value of ${E}_{\mathrm{acc}}\ensuremath{\ge}15\mathrm{MV}/\mathrm{m}$. In a first series of 27 industrially produced TTF cavities the average gradient at ${Q}_{0}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}5\ifmmode\times\else\texttimes\fi{}{10}^{9}$ was measured to be $20.1\ifmmode\pm\else\textpm\fi{}6.2\mathrm{MV}/\mathrm{m}$, excluding a few cavities suffering from serious fabrication or material defects. In the second production of 24 TTF cavities, additional quality control measures were introduced, in particular, an eddy-current scan to eliminate niobium sheets with foreign material inclusions and stringent prescriptions for carrying out the electron-beam welds. The average gradient of these cavities at ${Q}_{0}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}5\ifmmode\times\else\texttimes\fi{}{10}^{9}$ amounts to $25.0\ifmmode\pm\else\textpm\fi{}3.2\mathrm{MV}/\mathrm{m}$ with the exception of one cavity suffering from a weld defect. Hence only a moderate improvement in production and preparation techniques will be needed to meet the ambitious TESLA goal with an adequate safety margin. In this paper we present a detailed description of the design, fabrication, and preparation of the TESLA Test Facility cavities and their associated components and report on cavity performance in test cryostats and with electron beam in the TTF linac. The ongoing research and development towards higher gradients is briefly addressed.
逐年被引趋势
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
工程Particle accelerators and beam dynamics
Superconducting Materials and Applications · Particle Accelerators and Free-Electron Lasers
参考文献 10
此处列出前 3 条
引用本文 444
按被引量排序,此处列出前 3 条