100kW 3-phase ARCP soft switched SiC (S2SiC) inverter - design and in-lab test verification
Yushi Yang, Nan Lin, Yuheng Wu, Dongyu Jin, Zach Wehri, Muhammad Fasih Uddin, Brij Singh, Long Wu 等 9 位
University of Arkansas at Fayetteville John Deere (United States)
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
The auxiliary resonant commuted pole (ARCP) inverter is one of the most promising soft switching inverter topologies. In the ARCP inverter, resonant current supplied by the auxiliary circuit ensures soft switching operation. Successful soft switching of inverter results in lower level of electrical and thermal stresses on semiconductor power devices, and leads to lower temperature rise, and higher inverter efficiency. In this paper, 100kW ARCP 3-phase SiC inverter system was designed, fabricated, and double pulse test (DPT) test-verified to prove out feasibility for continuous operation. An excessive voltage overshoot was found under hard start, which poses a potential risk for premature failure of SiC power devices. To mitigate excessive voltage overshoot, authors have developed inverter start-up technique that was test-verified by DPT method. As expected with the developed soft-starting technique, power devices in the soft switched SiC (S2SiC) inverter don’t experience excessive voltage overshoot. The developed hardware for the S2SiC inverter and its control method is ready for interior permanent magnet (IPM) motor control. In this final paper, results from S2SiC inverter feeding a three-phase R-L load are included. Results to be obtained from a back-to-back motor dynamometer-based set-up will be reported in a future paper, where ARCP-based S2SiC inverter will drive an interior permanent magnet (IPM) motor with objective to prove out vitality and a compelling application of the 100kW S2SiC inverter.
逐年被引趋势
暂无年度引用数据
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
工程Silicon Carbide Semiconductor Technologies
Multilevel Inverters and Converters · Advanced DC-DC Converters
参考文献 5
此处列出前 3 条