Comparison Study of Interior Permanent Magnet Synchronous Machine with Conventional and Consequent Pole Rotor
Zhang Li, Kai Wang, Jian Li, Feng Li
Nanjing University of Aeronautics and Astronautics
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
This paper compares the electromagnetic performance of the interior permanent magnet synchronous machines (IPMSM) with conventional and consequent pole (CP) rotors, where the 12-slot stator and 10-pole rotor with concentrated windings are employed. Multi-objective optimization is performed in this paper. Both the conventional and CP rotors are optimized by genetic algorithm to achieve the maximum torque/PM volume and minimum torque ripple. Then the electromagnetic characteristics of the two machines, which including back-EMFs, torque characteristic, flux-weakening ability and efficiency are extensively compared. Finally, a conclusion could be reached by FEA that by using the CP rotor model, the machine can offer higher torque and efficiency, lower cogging torque and torque ripple, and better flux-weakening speed expansion performance.
逐年被引趋势
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
工程Electric Motor Design and Analysis
Sensorless Control of Electric Motors · Magnetic Properties of Alloys
参考文献 9
此处列出前 3 条
引用本文 16