Design and Discharge Characteristics Analysis of a 10-kV High-Voltage Current-Limiting Pre-Ionization Power System for Pulsed Plasma Thruster
Yahui Li, Chengming Qu, Xiaoqi Yin, Tianbai Deng, Mingsheng Tan, Shoubiao Zhang, Xiaopeng Wang
Anhui University Institute of Energy, Hefei Comprehensive National Science Center Chinese Academy of Sciences Hefei Institutes of Physical Science
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
Pulsed thrusters based on the compact torus (CT) fueling principle are regarded as promising high-power propulsion systems for the future, capable of achieving high thrust, high specific impulse, and plume-free operation. This is attributed to the structurally robust nature of the CT propellant, which can withstand immense electromagnetic forces and be accelerated to ultra-high velocities. However, a random breakdown delay ranging from tens to hundreds of microseconds occurs during the discharge in the formation zone. This delay not only complicates the system timing control but also directly reduces the energy injection efficiency of the power supply. To address these issues, this paper develops a$10-\text{kV}$high-voltage current-limiting pre-ionization system based on a coaxial minigun, specifically designed for the thruster. Combining the Townsend discharge theory and Paschen's Law, the theoretical derivation of the pre-ionization breakdown voltage threshold was conducted using Hartmann's experimental data on helium discharge. Based on these theoretical data, the pre-ionization power supply system was designed, and the circuit topology was optimized to successfully eliminate the uncontrolled breakdown phenomenon observed during initial testing. Finally, discharge breakdown experiments were conducted on the pre-ionization system under various gas injection pressures. The experimental results indicate that the proposed system can reliably break down helium. At pressures of 100 Pa and 200 Pa, the minimum breakdown voltages are 4.5 kV and 3.7 kV, respectively. Furthermore, with the increase of the pre-ionization voltage, the breakdown delay is significantly reduced from the hundredmicrosecond scale to the microsecond scale. This study provides a practical pre-ionization scheme and experimental support for optimizing the discharge performance and timing control strategies of pulsed plasma thrusters based on the CT fueling principle.
逐年被引趋势
暂无年度引用数据
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
工程Pulsed Power Technology Applications
Electromagnetic Launch and Propulsion Technology · Low-Pressure Plasma Processing and Diagnostics
参考文献 11
此处列出前 3 条