Temperature-Compensated pH Microelectrode Array Sensors Based on Copper-Oxide/Polyaniline Modification
Xin Wang, Lining Sun, Tian Wang, Yunbo Shi
Harbin University of Science and Technology Soochow University
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
pH is an important indicator of water quality. Therefore, developing accurate, efficient, and economical pH sensors is crucial. This paper presents a low-cost and highly robust miniature pH sensor chip with a temperature compensation function. The chip was manufactured using microelectricalmechanical systems technology. The surface of the chip comprised three three-electrode pH sensors and a Pt resistance temperature sensor. Moreover, CuO/polyaniline was modified for use as a pH-sensing material in the chip. To compensate for the temperature, a sandwich-plate sensor was utilized, which was integrated with a platinum-resistance heater. The experimental results show that the pH sensor had a high sensitivity of 0.288 mA/pH and high linearity of $R^{2} = 0.9998$ . Furthermore, the response time of the chip was less than 4 s, the sensitivity of the temperature sensor was $0.949\Omega /^{\circ }\text{C}$ , and the sensitivity of the temperature variations to the power of the heater was 0.3126 °C/mW. Finally, the pH sensor chip was further calibrated via multiple linear regression. Compared with commercial pH meters, the chip demonstrated high accuracy and remarkable temperature compensation.
逐年被引趋势
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
化学Analytical Chemistry and Sensors
Gas Sensing Nanomaterials and Sensors · Conducting polymers and applications