Multi-Data Center Tie-Line Power Smoothing Method Based on Demand Response
Ting Yang, Yuxing Hou, Shaotang Cai, Jie Yu, Haibo Pen
Tianjin University State Grid Corporation of China (China) State Grid Chongqing Electric Power Company (China)
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
Geographically distributed data centers (DCs) have emerged as significant energy consumers, which has led to the integration of renewable energy sources (RES) into DC power provisioning systems. However, the intermittent nature of RES and the randomness of user requests can cause significant fluctuations in DC operating power. It can be detrimental to the operation of IT equipment and lead to instability in the power grid. In this paper, aiming for tightly coupled interconnection scenarios with multi-data centers in varying regions, a multi-data center tie-line power smoothing method based on demand response is proposed. By modulating the power load of server clusters with workload scheduling, we establish a control model combined with intra-DC temporal task migration and inter-DC spatial task migration to deal with high-frequency power fluctuations. The uninterruptible power supply (UPS) battery control model is established to tackle low-frequency fluctuations. Furthermore, we design the two-stage heuristic power regulation algorithm to achieve the best practice of smoothing effect by real-time tracking of power targets after two-layer filtering. Finally, this paper performs a detailed performance simulation evaluation based on tracking data from a real DC and wind and photovoltaic (PV) new energy generation data, using four interconnected DC parks of different sizes across different regions as examples. The simulation results demonstrate that the proposed method effectively smoothing the multi-data center's tie-line power. Additionally, inter-DC temporal task migration serves as a viable solution to overcome the limitations of task migration response within a single DC, reducing the frequency of UPS battery bank charges and discharges, which in turn prolongs their service life. This approach facilitates the utilization of RES while maintaining power quality, and it also aids in reducing the escalating operation and maintenance expenses of DCs.
逐年被引趋势
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
工程Power Line Communications and Noise
Smart Grid Security and Resilience · Smart Grid and Power Systems
参考文献 41
此处列出前 3 条
引用本文 10
按被引量排序,此处列出前 3 条