A High-Performance 2×27 MVA Machine Test Bench Based on Multilevel IGCT Converters
Jie Shen, Stefan Schröder, Bo Qu, Yingqi Zhang, Kunlun Chen, Fan Zhang, Yulong Li, Yan Liu 等 10 位
General Electric (United States) Inovance (China)
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
In this paper, a high-performance 22 MW/27 MVA test bench using a pumpback topology is introduced for testing electrical machines. It proposes a cost-effective concept that works reliably even with a weak grid. A paralleling concept of two three-level integrated gate-commutated thyristor (IGCT) converters is presented. I generates a five-level pulse pattern with low harmonic distortion at 600-Hz carrier frequency and 80-Hz load frequency. The selected magnetic device minimizes the circulating current, which ensures the full power utilization of IGCT converters. Moreover, the control concept works reliably at 7.5 times of the carrier-to-load frequency ratio while there is a sine filter and a variable-frequency transformer between the converter and load machines. This test bench has been experimentally validated at the customer site.
逐年被引趋势
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
工程Multilevel Inverters and Converters
Electric Power Systems and Control · Electric Motor Design and Analysis