Natural-Circulation Tests With Water at 800 to 2000 Psia Under Nonboiling, Local Boiling, and Bulk Boiling Conditions
O.J. Mendler, A. S. Rathbun, N. E. Van Huff, A. H. Weiss
Westinghouse Electric (Japan)
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
Natural and forced-circulation test data for a closed-loop system are presented and analyzed. The data were obtained at pressures of 800, 1200, 1600, and 2000 psia from the natural-circulation loop at the Bettis Laboratory, using single rectangular channel test sections (0.100 in. × 1.0 in. × 27.0 in. long, 0.200 in. × 1.0 in. × 27.0 in. long, and 0.250 in. × 1.0 in. × 27.0 in. long). Heat fluxes ranged from 50,000 Btu/hr-sq ft to burnout with inlet subcoolings of 20, 70, and 100 deg F. The results showed that single and two-phase pressure drop, burnout heat flux, and riser density measured under natural-circulation operation are no different from those measured with forced circulation at the same thermal and fluid flow conditions. For the loop studied, it was shown that natural-circulation-loop flow rates can be predicted to within 10 per cent for both single and two-phase flow. Some data for slip ratios at liquid velocities less than 1/2 fps and for two-phase exit losses were obtained. Flow fluctuations were noted during some of the natural-circulation runs; these occurred before burnout heat flux was reached. In some instances these fluctuations were severe enough to cause a premature burnout.
逐年被引趋势
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
工程Nuclear Engineering Thermal-Hydraulics
Fluid Dynamics and Mixing · Heat Transfer and Boiling Studies
参考文献 0
引用本文 21
按被引量排序,此处列出前 3 条