Error Calibration of Cross Magnetic Gradient Tensor System with Total Least‐Squares Method
Cheng Chi, Dan Wang, Ronghua Tao, Zhentao Yu
PLA Navy Submarine Academy
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
The magnetic gradient tensor system configured by fluxgate magnetometers is subjected to different scale factors, three‐axis nonorthogonality, bias, and misalignment errors. All those errors above will influence the measurement precision directly, so the magnetic gradient tensor system must be calibrated before use. In this paper, an error calibration method of the magnetic gradient tensor system is proposed. The procedure of the proposed method is as follows. Firstly, the error calibration model of the single fluxgate magnetometer is established and generated an ellipsoid mathematical expression. To simplify the calculation, the ellipsoid mathematical expression is transformed into a linear model of intermediate variables, and then, error parameters are estimated by the total least‐squares method. Secondly, the orthogonal procrustes problem is adopted to calibrate misalignment errors. Finally, simulations and experiments with a cross magnetic gradient tensor system are carried out for verification of the proposed error calibration method. Results show that compared with the original least‐squares method, the proposed method can increase the measurement accuracy of the cross magnetic gradient tensor system greatly.
逐年被引趋势
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
工程Magnetic Field Sensors Techniques
Inertial Sensor and Navigation · Sensor Technology and Measurement Systems