Stator inter-turn short-circuit detection in doubly-fed induction generators using rotor current analysis
Nomentsoa Michel Raphael Rakotoarivelo, Nicolas Héraud, Eric Jean Roy Sambatra
Université de Corse Pascal Paoli Université d’Antsiranana
内容与影响
Early detection of inter-turn short-circuit faults in the stator windings of Doubly-Fed Induction Generators (DFIGs) is essential to ensure proper maintenance planning and avoid critical failures. This paper presents a technique to detect and quantify this type of fault to assess its severity. The proposed approach consists of analyzing the rotor currents of DFIGs in Park reference frame. A theoretical study is carried out, accompanied by experimental validation using a test bench and a data acquisition (DAQ) system. This study reveals a new fault indicator based on analysis of geometric shape of rotor currents. Quantifying the evolution of this indicator enables the estimation of defect severity with a relative error of 2%. Qualitative and quantitative analysis of it facilitates the maintenance supervisor’s decision-making process. The results demonstrate the potential of this approach, which is characterized by its simplicity, reliability and effectiveness.
逐年被引趋势
暂无年度引用数据
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
回答优先基于摘要、文献信息与可获取全文;依据不足时会明确说明。
学术脉络
学科主题
工程Machine Fault Diagnosis Techniques
Wind Turbine Control Systems · Wind Energy Research and Development
参考文献 45