Citrate regional anticoagulation of 500 ml/min of extracorporeal blood flow: an experimental study
Sebastiano Maria Colombo, Luigi Vivona, Michele Battistin, Vittorio Scaravilli, Alessandro Galli, Chiara Anzanello, Elisa Cipriani, F. Gori 等 16 位
Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico MultiMedica Ospedale San Giuseppe University of Milan
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
BACKGROUND: Regional citrate anticoagulation (RCA) is the most widespread technique which allows to perform extracorporeal treatments, avoiding the complications of systemic anticoagulation. Due to limited citrate clearance, RCA may be applied only to low extracorporeal blood flows (i.e., BF < 200 ml/min). In this proof of concept study, we developed an innovative RCA technique based on Ion Exchange Resin (i-ER) technology capable of regionally anticoagulating BF up to 500 mL/min. METHODS: Six healthy swine (41.0 ± 3.1 kg) were sedated, mechanically ventilated, and connected to a prototype extracorporeal circuit for continuous renal replacement therapy featuring a citrate-removal stage based on absorbent materials and replacement fluids. Blood flow was 500 ml/min. Sodium citrate was continuously infused at the circuit inlet (5 mmol/L). Heparin was continuously infused. Citrate concentration and Kaolin Heparinase thromboelastography (KH-TEG) were measured on arterial blood, extracorporeal blood downstream the citrate infusion port, and downstream the citrate-removal stage. Samples were collected at baseline, 2, 8, 15, 30, 45, 60, 90, and 120 min for citrate and at baseline, 2, 30, 60, and 120 min for KH-TEG. Calcium chloride was infused to maintain systemic ionized calcium within the physiological range. The experiment lasted 2 h. RESULTS: During the whole experiment, KH-TEG in the artery showed normal coagulation: reaction time (R) was 8.30[6.80-10.10] min, with Maximum Amplitude (MA) of 71.70[67.90-77.00] mm, while in the extracorporeal circuit, KH-TEG showed no sign of clot formation R > 60 min, MA = 0 mm. Citrate concentrations in blood samples were stable within 30 min, then slowly increased. The efficacy of the citrate-removal dropped from 93.8 ± 3.4% to 48.3 ± 1.5% at the beginning (2 min) and at the end (2 h), respectively (p < 0.001), due to loss of efficiency of the iERs. CONCLUSIONS: This study demonstrates that iER-based RCA is a feasible and effective technique for regional anticoagulation of extracorporeal blood flow up to 500 mL/min for 60 min without significant complications.
逐年被引趋势
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
生物医学Trauma, Hemostasis, Coagulopathy, Resuscitation
Acute Kidney Injury Research · Hemostasis and retained surgical items
参考文献 56
此处列出前 3 条
引用本文 2
按被引量排序,此处列出前 3 条