Numerical study of the use of photovoltaic-Trombe wall in residential buildings in Tibet
J. Ji, H Yi, Gang Pei, H. F. He, Chongwei Han, Chenglong Luo
University of Science and Technology of China
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
In the current paper, the thermal and electrical performance of photovoltaic (PV)- Trombe wall (PV-TW) used in Tibetan residential buildings is investigated, and two performance influencing factors are analysed. Based on the original model, the PV-TW's model for residential buildings is updated, and then a simple design is performed for a given residential building in Tibet. The results show that the indoor temperature increases linearly, whereas the electrical efficiency remains almost constant, when the PV-TW's width increases. In addition, thermal insulation is found to be quite effective to improve the thermal performance, whereas it decreases the electrical performance only a little. After choosing a width of 1.70 m, the average indoor temperatures are 10.2 °C and 24.0 °C for PV-TW system with and without thermal insulation, respectively. Besides, the average electrical power can satisfy the requirement of 100W, with an electrical efficiency of 10–11 per cent.