Mass Spectrometric Analysis of Chemical Warfare Agents and Their Degradation Products in Soil and Synthetic Samples
Paul A. D’Agostino, James R. Hancock, C. L. Chenier
Defence Research and Development Canada
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
A packed capillary liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) method was developed for the identification of chemical warfare agents, their degradation products and related compounds in synthetic tabun samples and in soil samples collected from a former mustard storage site. A number of organophosphorus and organosulfur compounds that had not been previously characterized were identified, based on acquired high-resolution ESI-MS data. At lower sampling cone voltages, the ESI mass spectra were dominated by protonated, sodiated and protonated acetonitrile adducts and/or their dimers that could be used to confirm the molecular mass of each compound. Structural information was obtained by inducing product ion formation in the ESI interface at higher sampling cone voltages. Representative ESI-MS mass spectra for previously uncharacterized compounds were incorporated into a database as part of an on-going effort in chemical warfare agent detection and identification. The same samples were also analyzed by capillary column gas chromatography (GC)-MS in order to compare an established method with LC-ESI-MS for chemical warfare agent identification. Analysis times and full-scanning sensitivities were similar for both methods, with differences being associated with sample matrix, ease of ionization and compound volatility. GC-MS would be preferred for organic extracts and must be used for the determination of mustard and relatively non-polar organosulfur degradation products, including 1,4- thioxane and 1,4-dithiane, as these compounds do not ionize during ESI-MS. Diols, formed following hydrolysis of mustard and longer-chain sulfur vesicants, may be analyzed using both methods with LC-ESI-MS providing improved chromatographic peak shape. Aqueous samples and extracts would, typically, be analyzed by LC-ESI-MS, since these analyses may be conducted directly without the need for additional sample handling and/or derivatization associated with GC-MS determinations. Organophosphorus compounds, including chemical warfare agents, related compounds and lower volatility hydrolysis products may all be determined during a single LC-ESI- MS analysis. Derivatization of chemical warfare agent hydrolysis products and other compounds with hydroxyl substitution would be required prior to GC-MS analysis, giving LC-ESI-MS a definite advantage over GC-MS for the analysis of samples containing chemical warfare agents and/or their hydrolysis products.
逐年被引趋势
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
生物医学Pesticide Exposure and Toxicity
Mass Spectrometry Techniques and Applications · Pesticide Residue Analysis and Safety
参考文献 21
此处列出前 3 条
引用本文 65
按被引量排序,此处列出前 3 条