Loss analysis of frequency-conversion speed-regulation system of mine high-voltage multilevel ANPC
LI Na, XU Yanping, HE Fengyou
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
Taking frequency-conversion speed-regulation system of high-voltage five-level active neutral point clamped ANPC as a research object, switching loss, capacitance loss and transmission loss of the system were carried on quantitative analysis on the basis of introducing mathematical topology model of ANPC five-level and PWM modulation method. The analysis results show that although loss type of the ANPC five-level topology is more, but it has significant advantage in controlling switching loss, and can make the frequency-conversion speed-regulation system of motor have more efficient operation.
逐年被引趋势
暂无年度引用数据
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
工程Multilevel Inverters and Converters
Electric Power Systems and Control · Sensorless Control of Electric Motors