Development and application of decontamination methods for the re-use of laboratory grade plastic pipette tips
Sang Hyuk Lee, William Kastor, Xiao Liang Fu, Vikas Soni, Michael Keidar, Marc D. Donohue, Steve Wood, Enusha Karunasena
United States Food and Drug Administration Center for Devices and Radiological Health Johns Hopkins University Office of Science
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
During the SARS-CoV-2 pandemic, a need for methods to decontaminate and reuse personal protective equipment (PPE) and medical plastics became a priority. In this investigation we aimed to develop a contamination evaluation protocol for laboratory pipette tips, after decontamination. Decontamination methods tested in this study included cleaning with a common laboratory detergent (2.5% Alconox® solution followed with steam decontamination), exposure of ozone vapor at 250 and 14400 PPM * minute, and exposure to cold atmospheric plasma (CAP). All tips (control and experimental groups) were introduced to the methods described, while tips exposed to DNA extracts of Aeromonas hydrophila (ATCC-23211) were assessed for experimental groups. Decontamination was determined by turnover ratio and log reduction in detectable genomic material on the contaminated products using real-time quantitative PCR (qPCR) assay. Our results showed, cleaning tips with lab detergents along with steam decontamination removed genetic material, resulting in the highest log reduction, compared with ozone or CAP treatments. Detergent/washing methods showed the second highest turnover ratio (95.9%) and log reduction (5.943). However, the excessive residue (post- cleaning) on the plastic, within inner filters, and tip boxes suggested that washing with lab detergents was not favorable for reuse. Ozone vapor at 14400 PPM * minute showed the highest turnover ratio (98.4%) and log reduction (4.511). CAP exposure with tips inverted (the tip end exposed closer to the plasma flame) for 1 minute showed a turnover ratio of (68.3%) and log reduction (4.002). Relatively, lower turnover ratio and log reduction of CAP could be improved by optimization, such as increasing the exposure time. Future testing would provide fine-tuned conditions for CAP-specific decontamination of plasticware. In this study we were able to provide fundamental insight into a non-traditional decontamination method for single-use plasticware that could render these products reusable.
逐年被引趋势
暂无年度引用数据
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
生物医学Infection Control and Ventilation
Healthcare and Environmental Waste Management · SARS-CoV-2 detection and testing
参考文献 16
此处列出前 3 条