To address the limitations of individual battery thermal management technologies, this study proposes a hybrid battery thermal management system coupling static immersion cooling with refrigerant-based direct cooling. The system employs parallel upper and lower direct cooling plates, with the refrigerant flow split regulated to enhance buoyancy-driven convection within the sealed immersion chamber. Numerical simulations are conducted to compare an R134a direct cooling system with a 50% ethylene glycol solution indirect cooling system over total flow rates of 6–18 L⋅min−1 and upper plate flow ratios of 10–90%. The effects of the total flow rate and flow distribution on the pressure drop, battery temperature, temperature uniformity, flow characteristics, and pumping power are systematically evaluated. The R134a direct cooling system reduces the average battery temperature by approximately 0.5–1.0 °C compared with the indirect cooling system. Increasing the upper plate flow ratio strengthens the natural convection within the immersion chamber and alleviates vertical temperature non-uniformity, whereas excessive flow redistribution weakens the cooling capacity of the lower plate. A Kriging surrogate model coupled with a multi-objective genetic algorithm identifies the optimal condition at a total flow rate of 8.82 L⋅min−1 and an upper plate flow ratio of 56.45%. Relative to the baseline condition of 9 L⋅min−1 and an upper plate flow ratio of 10%, the optimized condition reduces the average battery temperature, maximum temperature difference, and pumping power by 10.1%, 7.2%, and 52.1%, respectively, while maintaining a low cell temperature standard deviation of 0.032 °C.
逐年被引趋势
暂无年度引用数据
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
工程Advanced Battery Technologies Research
Heat Transfer and Optimization · Refrigeration and Air Conditioning Technologies
参考文献 39
此处列出前 3 条