Protection Criteria of Cathodically Protected Pipelines Under AC Interference
Luca Paterlini, Andrea Marinelli, Andrea Brenna, Marco Ormellese
Politecnico di Milano
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
Carbon steel structures employed to convey hydrocarbons and other dangerous fluids, such as oil or flammable liquids, are equipped with degradation prevention systems, which typically consist of a cathodic protection (CP) system combined with an external insulating coating, both designed to reduce the corrosion rate below 10 µm/year. The presence of electrical interference, both AC and DC, can cause significant corrosion damage to metallic structures, even when CP is applied. DC interference is determined by the presence of a third-party CP system or public transportation system. AC interference may occur through conduction or induction mechanisms, caused by high-voltage powerlines or high-speed trains, powered by AC. Both interferences may lead to localized corrosion at coating defects, despite compliance with the −0.850 V saturated Cu/CuSO4 reference electrode (CSE) protection criterion. Considering AC-induced corrosion, both field failures and laboratory investigations have demonstrated that corrosion can occur at industrial frequencies, and when CP is applied following the standards. Even though AC-induced degradation is generally not as severe as DC interference, uncertainties remain regarding the protection potential range necessary to achieve acceptable corrosion prevention under AC interference. To formulate a CP criterion under AC interference, weight loss measurements were conducted on carbon steel samples under cathodic protection in solutions that simulate real soil conditions. Carbon steel coupons protected by CP were interfered with AC densities ranging from 1 A/m2 to 800 A/m2 for four months. During this time interval, polarization potential, protection current density and AC density were monitored. Based on the experimental data gathered during this study, a proposal for a risk map is also suggested. The results indicate that overprotection (potentials < −1.2 V CSE) represents the most dangerous scenario when AC interference is involved.
逐年被引趋势
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
材料 / 化学Corrosion Behavior and Inhibition
Structural Integrity and Reliability Analysis · Engineering Diagnostics and Reliability
参考文献 22
此处列出前 3 条
引用本文 2
按被引量排序,此处列出前 3 条