Application of Quartz LA-ICP-MS Analysis in the Evaluation of High-Purity Quartz Deposits
Hongjie Wang, Fangyue Wang, Yan Zhao, Xueyi Xu, Baodi Wang, Yu Fan, Liang Zhang, Feng Guo
Hefei University of Technology Ministry of Natural Resources Chinese Academy of Geological Sciences East China University of Technology
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
High-purity quartz is considered one of the world’s scarce mineral resources. During the evaluation process of high-purity quartz raw material deposits, metallurgical purification evaluation experiments are often required to assess the quality of quartz. However, these experiments are costly and time-consuming, and have other drawbacks. In addition, high-purity quartz is difficult to analyze by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) due to its extremely low impurity content, resulting in low accuracy. It is therefore essential to assess the validity of the results obtained from LA-ICP-MS analysis of quartz minerals and to establish an efficient and cost-effective method for the evaluation of high-purity quartz deposits. We selected samples from the high-purity quartz deposits at Yamansu and Taerlang in Xinjiang, which exhibit uniform cathodoluminescence (CL) characteristics. We conducted trace element analysis of quartz using four methods: nanosecond laser dot ablation, femtosecond laser dot ablation, femtosecond laser line ablation, and femtosecond laser area scanning. Combined with the results of metallurgical purification, the stability of quartz LA-ICP-MS analytical data and the proximity to the purification results are evaluated by using two methods, i.e., the comparison of casting diagrams and the construction of comprehensive stability and proximity evaluation models. The results show that the femtosecond laser line ablation has the best stability in the analysis of the elements of quartz Al, Ti, Li, and B and the highest proximity to the results of metallurgical purification, and the nanosecond laser dot ablation also has better stability and proximity, while femtosecond laser surface scanning data quality is relatively poor due to unavoidable inclusions and co-associated minerals. Geological mapping using in situ quartz trace element content can effectively delineate the potential areas of high-purity quartz, and the results of analysis and the metallurgical purification results have a high degree of proximity. Therefore, this paper recommends the use of femtosecond laser line ablation as a highly efficient exploration method for high-purity quartz deposits.
逐年被引趋势
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
物理Geological and Geochemical Analysis
Analytical chemistry methods development · Laser-induced spectroscopy and plasma
参考文献 16
此处列出前 3 条
引用本文 5