Redesign of the Axial Cooling Fan for an Air-cooled Diesel Engine
Z. Liu, G. Ren, X. Zhang, X. Wang, X. Li
Tianjin University China North Industries Group Corporation (China)
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
As the power of air-cooled diesel engine increases, the problems of insufficient total pressure and flow rate of the cooling fan have become increasingly prominent. This study proposes a redesign strategy for the axial cooling fan of high-power air-cooled diesel engines to resolve severe overheating under rated operating condition. Firstly, the performance of the baseline fan is evaluated through the cooling system test, and the aerodynamic test as well as numerical simulation, resulting in a specific design target for the high-load fan. Subsequently, based on the assumption of constant twist velocity and axial outflow, the fan inlet negative pre-swirl angle is calculated. Then, the impeller and guide vane matching design for the high-load fan is completed based on the cascade design theory. The test results show that under the design condition, the total pressure and static pressure of the high-load fan reach 5439 Pa and 3257 Pa respectively, increasing by 90% and 79% compared to the baseline fan. The engine thermal balance experiment indicates that under the rated power, the high-load fan has reduced the cylinder temperature by 15.6 ℃, and obviously alleviated the overheating problem of the engine.
逐年被引趋势
暂无年度引用数据
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
工程Turbomachinery Performance and Optimization
Heat Transfer and Optimization · Cavitation Phenomena in Pumps