Corrosion Control Issues for Marine Vessel Copper-Nickel Boxcoolers
D G John, David Buxton, A. R. Piercy, P. Ernst, C de Kwant, H Piket, L Leentfaar
Intertek (United Kingdom)
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
Copper-Nickel (CuNi) alloys (sometimes referred to as Cunifer) have good corrosion resistance and natural fouling resistance in seawater and are used extensively for seawater systems, including heat exchangers. For smaller marine vessels (for example tugs, support vessels, etc.) the heat exchanger tubes are simply placed inside a seachest, open to the sea, to allow cooling creating a box cooler arrangement. To maintain the natural anti-fouling properties the CuNi needs to be isolated from the vessel’s cathodic protection (CP) system. However, depending on the configuration of the cooler and seachest as well as the position of the cathodic protection anodes within the seachest, isolated coolers can be at risk of stray current corrosion problems. As the tube walls are thin, even low rates of corrosion should be avoided. The paper will describe the overall problems encountered and methods developed to prevent stray current corrosion damage, whilst maintaining the natural marine fouling resistance of the CuNi.
逐年被引趋势
暂无年度引用数据
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
材料 / 化学Material Properties and Applications
Mechanical Failure Analysis and Simulation · Corrosion Behavior and Inhibition
参考文献 2