Impact of Dimensional Variability of Primary Packaging Materials on the Break-Loose and Gliding Forces of Prefilled Syringes
Ramadan Alkeefo, Christian Hotz, Daniel Kolacyak
University of Applied Sciences Ravensburg-Weingarten Vetter (Germany)
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
A prefilled syringe (PFS) should be able to be adequately and consistently extruded during injection for optimal safe drug delivery and accurate dosing. To facilitate appropriate break-loose and gliding forces (BLGFs) required during injection, certain primary packaging materials (PPMs) such as the syringe barrel and plunger are usually coated with silicone oil, which acts as a lubricant. Due to its direct contact with drug, silicone oil can increase the number of particles in the syringe, which could lead to adverse interactions. Compliance with regulatory-defined silicone oil quantities in certain drug products, such as ophthalmics, presents a trade-off with the necessity for desirable low and consistent BLGF. In addition to its siliconization, the dimensional accuracy of the PPM has an important role in controlling the BLGF. The dimensions of the PPM are individualized depending on the product and its design and have certain tolerances that must be met during manufacturing. Most studies on ophthalmics focused on the adverse interactions between silicone oil and the drug. To the authors' knowledge, there have been no public studies so far that have investigated the impact of the dimensional variability of the PPM on the BLGF in ophthalmic PFSs. In this study, we applied advanced optical shaft and tactile measuring technologies to investigate this impact. The syringes investigated were first sampled during aseptic production and tested for the BLGF. Subsequently, defined dimensions of the PPM were measured individually. The results showed that the dimensional variability of the PPM can have a negative impact on the BLGF, despite their conformity to specifications, which indicates that the currently available market quality of PPMs is improvable for critical drug products such as ophthalmics. This study could serve as an approach to define product-specific requirements for primary packaging combinations and thus appropriate specifications based on data during the development stage of drug products.
逐年被引趋势
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
工程Intravenous Infusion Technology and Safety
Drug Solubulity and Delivery Systems · Injection Molding Process and Properties
参考文献 0
引用本文 2
按被引量排序,此处列出前 3 条