Numerical simulations of ice accretion and anti-icing for large-scale wind turbines
Guangyu Wang, Xiaohong Huang, Cong Fei, Zhiyuan He, Wenqiang Zhang
阅读操作
确认中在文库中上传 PDF 后可生成中文音频讲解。
摘要与影响
As one of the core components in wind-to-electric energy conversion systems, wind turbine generators are rapidly expanding in global deployment. Blade icing, a phenomenon that severely compromises operational efficiency, has emerged as a critical challenge for the industry. With the growing demand for wind energy, turbine sizes have increased significantly, yet research on full-scale turbine icing characteristics and anti-icing strategies remains limited. Therefore, this study employs numerical simulations to investigate the icing distribution characteristics of a three-dimensional, large-scale wind turbine with a 200 m rotor diameter. The simulation results are compared with natural icing observations from unmanned aerial vehicles to analyze the aerodynamic impact of icing on large-scale wind turbines, and to determine the anti-icing zones and strategies. Results indicate that ice accretion predominantly occurs along the leading edge, and minor ice accretion can also be observed at the tip’s trailing edge due to local airfoil geometry. The maximum ice thickness decreases from the blade tip toward the root, and remains comparable at radial positions below 40% (r/R≤40%) under different icing conditions. Based on these accretion patterns, the anti-icing zone is determined as s/clocal≤0.25. Within this zone, the blade leading edge is divided into several heating zones along the spanwise direction, and the required heat-flux-density distribution is further analyzed. The results show that the closer the heating zone is to the blade tip, the higher the required heat flux density. For the same heating zone, the greater the temperature difference between the anti-icing temperature and the ambient icing temperature, the higher the required heat flux density. For example, at an ambient icing temperature of 255 K, zone1 near the blade tip requires 55 kW/m2 when the surface temperature is 318 K, but only 16 kW/m2 at 278 K. These findings provide a reference for determining anti-icing zones and designing anti-icing power for large-scale wind turbine blades.
逐年被引趋势
暂无年度引用数据
关键指标
同类平均 = 1
同领域 · 同年份 · 同类型
Google Scholar 与 OpenAlex 的被引统计范围不同,数值存在差异属正常。
AI 辅助阅读
依据:摘要
可就本文提问;依据不足时会说明。
学术脉络
学科主题
工程Icing and De-icing Technologies
Wind Energy Research and Development · nanoparticles nucleation surface interactions